Hardware and software


EMMA-WIN Data logger Support Software:

  • Program editor
  • Real-time monitor (displays data on-line)
  • Terminal emulator
  • Automatic data collection from multiple remote stations
  • Communication data support
  • Easy mode

EMMA Data logger Support Software

  • Windows ® graphical interface
  • Charts, graphs and reports
  • Wind rose
  • Database editor
  • Program editor
  • Automatic data collection and station calling – an unlimited number of stations
  • Real time measurement and real time display of measurement

EMMA Light Data logger Support Software:

  • Editor programa
  • Real-time monitor
  • Terminal emulator
  • On-line new and historical data
  • Supports communication with the station
  • Easy mode

Data Logger X16 for data collection (computer in the meteorological station)

  • 20 analog input and output channels
  • Expandable up to 200 channels
  • 4 voltage outputs to power sensors
  • 4 input channel impulses (counters)
  • 6 digital control outputs
  • Low power consumption
  • Large internal memory for data and software

Data Logger X8 for data collection (computer in the meteorological station)

  • 8 single-ended or 4 differential analog input channels
  • Expandable up to 50 channels
  • 6 voltage outputs to power sensors
  • Up to 4 input channel impulses (counters)
  • 6 digital control outputs
  • Low power consumption
  • No memory for data – a breakdown in communication means data is loss

CR-X modul for expanding the number of input channels

  • 48 single-ended or 32 differential input channels
  • 16 “full bridge” input channels

CR -XI Modul za upravljačke izlaze:

  • Number of channels: 2
  • The principle of operation: a non-contact switch
  • Control voltage: High level: 5 V DC, Low level: 0 V
  • Input power: 12 V (<50 V)
  • Output: 12 VDC
  • Current drain: <0.05 mA
  • Rated power: <1.5 A @ 12VDC

The sensors for measuring parameters (selection of sensors for professional weather stations)

Wind-01 wind measuring sensor

  • Measuring range:
    • Wind speed: 0-75 m / s.
    • Wind direction: 0-360 °
  • Accuracy:
    • Wind speed:
      • ± 1 m / s (0-20m / s)
      • ± 5% (> 20 m / s)
    • Wind Direction: ± 7 °
  • Signal output
  • Wind speed: magnetic switch
  • Wind direction: potentiometer

Wind-02 wind measuring sensor (speed and/or direction):

  • Measuring range:
    • Wind speed: 0 – 50 m / s
    • Wind direction: 0-360 °
  • Accuracy:
    • Wind speed: ± 0,5 m / s
    • Wind direction: ± 5 °
  • Signal output:
    • Wind speed: magnetically induced AC voltage
    • Wind direction: potentiometer
  • Options:
    • 02 WS & WD: 0 – 1 VDC output (direction and speed)
    • 02 WS: 0-1 VDC output (speed)
    • 02 WD: 0-1 VDC output (direction)

Wind-03 Sensor for wind monitoring:

  • Measuring range:
    • Wind speed: 0 – 100 m / s.
    • Wind direction: 0-360 °
  • Accuracy:
    • Wind speed: ± 0,3 m / s, 1% of reading
    • Wind direction: ± 3 °
  • Signal output:
    • Wind speed: magnetically induced AC voltage
    • Wind direction: DC voltage – potentiometer
  • Options:
    • 03V sa 0 – 5 VDC output
    • 03L s 4 – 20 mA output

Temperature and humidity sensor T/RH probe TRH

  • Measurement range
    • Temperature: -40 °C – 60 °C
    • Vlažnost: 0 to 100%
  • Accuracy:
    • Temperature: ± 0,3 °C
    • Vlažnost: ± 1,5% (10 – 95%)  ± 2,5% (<10% ili> 95%)

Temperature and air humidity sensor T/RH probe TRH2

  • Measurement range
    • Temperature: -40 °C to + 60 °C
    • Humidity: 0 do 100%
  • Accuracy:
    • Temperature: ± 0,3 ℃ (-20 °C to 40 °C) ± 0,5 °C (-40 ℃ to + 60 °C)
    • Humidity: ± 3% (0 – 90%) ± 5% (90 – 98%)

Temperature and air humidity sensor T/RH probe TRH3

  • Measurement range
    • Temperature: -40 °C to + 60 °C
    • Humidity: 0 to 100% RH
  • Accuracy:
    • Temperature: ± 0,15 °C
    • Humidity: ± 1,0% RH

T/RH solar radiation probe protector

  • Material: UV-stabilized white thermoplastic plates
  • Principle: natural ventilation
  • No power required
  • Type with 8 boards
  • Type with 4 rings

SOL-01 silicon pyranometer (UV radiation measurement)

  • Range: 400 – 1100 nm
  • Sensitivity: 48 UV / W / m2
  • Linearity:: 1% do 3000 W / m2
  • Točnost: ± 3%
  • Vrijeme odziva: 3 μs

SOL-02 Pyranometer

  • Range: 305 – 2800 nm
  • Sensitivity: 10 – 40 UV / W / m2
  • Instability: <1% annual change
  • Non-linearity: ± 2,5%
  • Response time 95% za 18 Sec
  • Temperature range: -40 ℃ do + 80 °C

NSOL Total radiation sensor – Pyrgeometer sensors

  • Temperature range: -40 do +80 °C
  • Range: 0 – 2000 W/m2
  • Temperature sensor: Thermistor
  • Temperature sensor: Can be added if desired

Pyranometer (short-wave)

  • Pyranometer ISO classification: second class
  • Range: 305 – 2800 nm
  • Calibration traceability

WRR Pyrgeometer (long-wave)

  • Range: 4.500 – 50.000 nm
  • Calibration traceability: NIST
  • Window heating offset @ 1000 W/m2 solar radiation: <15 W/m2
  • Heat output: 5 Watt @ 12VDC

Pyr – 01 Pyranometer

  • Range: 400 – 1100 nm
  • Signal output: 0-1 VDC
  • Measuring range: 0 – 1400 W / ㎡
  • Accuracy: <4%
  • Response time: <50 ms
  • Electricity supply: 12-24 VDC/7mA

BP-01 Pressure sensor

  • Measuring range: 630 – 1130 mbar ili hPa (18,6 – 33.4in Hg.).
  • Resolution: unlimited
  • Operating temperature: -40 °C do + 85 °C
  • Temperature compensation: 0 °C do + 70 °C
  • Accuracy: ± 0,125% FS
  • Power supply: 10 – 24V
  • Power consumption:
    • Active 5mA @ 12VDC
    • Static 1.1mA @ 12VDC
  • Signal output: 0-2 VDC

SU-10 UVA Sensor

  • Spectrum: 315-380 nm
  • Detector: GaAsp
  • Linearity error: better than 1%
  • Absolute Calibration error: typically <3% (max. 5%)
  • The long stability: <± 2%
  • Response time: 10 ms

HF-01 Heat flow sensor

  • Sensitivity: 50 μV / W / m2
  • Resistance (nominal):: 2 Ω
  • Measuring range: 2000 do 2000W / m2
  • The temperature dependence: <0,1% / °C
  • Response time: ± 4 min (same ground)

HFT-3 Sensor heat flow to the ground

  • Nominal calibration factor: 40 W / m2 / mV
  • Resistance (nominal): 2 Ω
  • Nominal size: 38.56mm, diameter * 3,93 mm thick
  • Thermal conductivity: 1.22 Wm-1K-1
  • Cable: Shield 2-conductor, 7.6m length

E-100 Meter evaporationa and evaporation vessel

  • Dimensions:
    • Height: 27 1/2 inches
    • Diameter: 8 inches
    • Float: 4 inch diameter plastic
  • Potentiometer:
    • Accuracy: 0.25%
    • Rotation: continuous
    • Resistance: 1000 oHm
    • Operating temperature: -40 °C – +60 °C

IP Infracrveni Radiometar

  • Field of View (FOV): 22 ° half angle
  • Accuracy:
    • -15 do +60 °C ± 0,2 ° C absolute accuracy
    • ± 0,1 °C uniformity and repeatability
    • -55 do +80 ° C ± 0,5 ° C absolute accuracy
    • ± 0,3 °C uniformity and repeatability
  • Wavelength: 8-14 um
  • Response time: less than 1 second
  • Operating ambient temperature:
    • 55 °C to +80 °C
    • 0 – 100% RH (non-condensing)

GT1 universal temperature probe (water, air, soil):

  • Measuring rangee: -40 to +60 °C
  • Accuracy:
    • ± 0,3  °C(-20 °C to +40)
    • ± 0,5 °C (-40 °C to +60)
  • For the measurement of the air, soil and water temperature

GT2 Univerzalna temperaturna sonda:

  • Measuring range: – 40 °C do + 90 °C
  • Accuracy:
    • ± 0,3 °C (- 20 to 40 °C)
    • ± 0,5 °C (- 40 to + 60 °C)
    • ± 0,7 °C (+ 60 to +90 °C)

RG-1 Pluviometer

  • Sensor type: tipping bucket
  • Hole diameter: 200 mm
  • Material: bronze
  • Sensitivity: 0,5 mm
  • Accuracy:
    • ± 0,5 mm below 20mm/hr
    • 20mm/hr to 120 mm / hr ± 3%
  • Signal output: non-contact reed switch
  • Housing: inox
  • Air balloon leveling included

RG-AB (type M and I) rain gauges

  • Sensor type: tipping bucket
  • Sensitivity: 0,2 mm (M serije); 0,01 inches (I series)
  • Output: contact closure
  • Housing material: UV stabilized ABS plastic
  • Power supply: Not required
  • Air balloon for leveling (M/I-AB )

UL-01 Sensor for measuring the level of water or snow with ultrasound

  • Measuring range: 0,5 do 10 meters
  • Beam Width: 22 degrees
  • Accuracy: ± 1 cm ili 0,4 % of distance to the finish
  • Resolution: 3 mm
  • Temperature range: -30 do +70 °C
  • Analog output: 0-2 VDC ili 0-5 VDC
  • Power: 12 do 24 V, 50 mA

LW-4 Underwater pressure transducers

  • Measuring range: 0 – 15 inches (second measuring range: 0 – 30 inches , 0 – 60 inches )
  • Bursting pressure: 10 x full scale
  • Static accuracy: ± 0,2% full scale measurement
  • Power supply: 10 – 36 VDC
  • Housing material: Steel SS304L
  • Output: 0,4-0,2 VDC (ili 4 – 20 mA)
  • Cable length: 7.5m  ili 15m ili 30m standard

LW-5 Underwater pressure converters

  • Measuring range: 0-5 through 0-300 psi
  • Bursting pressure: 2,0 x full scale
  • Static accuracy: ± 0,25% full scale measurement
  • Power supply: 9-30 VDC
  • Wetted material: SS316
  • Working temperature : -10 °C to +60 °C
  • Compensation temperature the range: 0 °C to +50 °C
  • Output: 0,4 do 2,0 V ili 4-20 mA
  • Fuses: polarity, exceed / short circuit

SP-20 Solar panel

  • Max. power: 21 Watt
  • The voltage at the peak: 17,4 VDC
  • Electricity at the peak: 1.21A
  • Optional USM 20 carrier

SP-30 Solar panel

  • Max. power: 32 Watt
  • The voltage at the peak: 17,4 VDC
  • Electricity at the peak: 1.21A
  • Optional USM 30 carrier