EMMA-WIN Data logger Support Software:
- Program editor
- Real-time monitor (displays data on-line)
- Terminal emulator
- Automatic data collection from multiple remote stations
- Communication data support
- Easy mode
EMMA Data logger Support Software
- Windows ® graphical interface
- Charts, graphs and reports
- Wind rose
- Database editor
- Program editor
- Automatic data collection and station calling – an unlimited number of stations
- Real time measurement and real time display of measurement
EMMA Light Data logger Support Software:
- Editor programa
- Real-time monitor
- Terminal emulator
- On-line new and historical data
- Supports communication with the station
- Easy mode
Data Logger X16 for data collection (computer in the meteorological station)
- 20 analog input and output channels
- Expandable up to 200 channels
- 4 voltage outputs to power sensors
- 4 input channel impulses (counters)
- 6 digital control outputs
- Low power consumption
- Large internal memory for data and software
Data Logger X8 for data collection (computer in the meteorological station)
- 8 single-ended or 4 differential analog input channels
- Expandable up to 50 channels
- 6 voltage outputs to power sensors
- Up to 4 input channel impulses (counters)
- 6 digital control outputs
- Low power consumption
- No memory for data – a breakdown in communication means data is loss
CR-X modul for expanding the number of input channels
- 48 single-ended or 32 differential input channels
- 16 “full bridge” input channels
CR -XI Modul za upravljačke izlaze:
- Number of channels: 2
- The principle of operation: a non-contact switch
- Control voltage: High level: 5 V DC, Low level: 0 V
- Input power: 12 V (<50 V)
- Output: 12 VDC
- Current drain: <0.05 mA
- Rated power: <1.5 A @ 12VDC
The sensors for measuring parameters (selection of sensors for professional weather stations)
Wind-01 wind measuring sensor
- Measuring range:
- Wind speed: 0-75 m / s.
- Wind direction: 0-360 °
- Accuracy:
- Wind speed:
- ± 1 m / s (0-20m / s)
- ± 5% (> 20 m / s)
- Wind Direction: ± 7 °
- Wind speed:
- Signal output
- Wind speed: magnetic switch
- Wind direction: potentiometer
Wind-02 wind measuring sensor (speed and/or direction):
- Measuring range:
- Wind speed: 0 – 50 m / s
- Wind direction: 0-360 °
- Accuracy:
- Wind speed: ± 0,5 m / s
- Wind direction: ± 5 °
- Signal output:
- Wind speed: magnetically induced AC voltage
- Wind direction: potentiometer
- Options:
- 02 WS & WD: 0 – 1 VDC output (direction and speed)
- 02 WS: 0-1 VDC output (speed)
- 02 WD: 0-1 VDC output (direction)
Wind-03 Sensor for wind monitoring:
- Measuring range:
- Wind speed: 0 – 100 m / s.
- Wind direction: 0-360 °
- Accuracy:
- Wind speed: ± 0,3 m / s, 1% of reading
- Wind direction: ± 3 °
- Signal output:
- Wind speed: magnetically induced AC voltage
- Wind direction: DC voltage – potentiometer
- Options:
- 03V sa 0 – 5 VDC output
- 03L s 4 – 20 mA output
Temperature and humidity sensor T/RH probe TRH
- Measurement range
- Temperature: -40 °C – 60 °C
- Vlažnost: 0 to 100%
- Accuracy:
- Temperature: ± 0,3 °C
- Vlažnost: ± 1,5% (10 – 95%) ± 2,5% (<10% ili> 95%)
Temperature and air humidity sensor T/RH probe TRH2
- Measurement range
- Temperature: -40 °C to + 60 °C
- Humidity: 0 do 100%
- Accuracy:
- Temperature: ± 0,3 ℃ (-20 °C to 40 °C) ± 0,5 °C (-40 ℃ to + 60 °C)
- Humidity: ± 3% (0 – 90%) ± 5% (90 – 98%)
Temperature and air humidity sensor T/RH probe TRH3
- Measurement range
- Temperature: -40 °C to + 60 °C
- Humidity: 0 to 100% RH
- Accuracy:
- Temperature: ± 0,15 °C
- Humidity: ± 1,0% RH
T/RH solar radiation probe protector
- Material: UV-stabilized white thermoplastic plates
- Principle: natural ventilation
- No power required
- Type with 8 boards
- Type with 4 rings
SOL-01 silicon pyranometer (UV radiation measurement)
- Range: 400 – 1100 nm
- Sensitivity: 48 UV / W / m2
- Linearity:: 1% do 3000 W / m2
- Točnost: ± 3%
- Vrijeme odziva: 3 μs
SOL-02 Pyranometer
- Range: 305 – 2800 nm
- Sensitivity: 10 – 40 UV / W / m2
- Instability: <1% annual change
- Non-linearity: ± 2,5%
- Response time 95% za 18 Sec
- Temperature range: -40 ℃ do + 80 °C
NSOL Total radiation sensor – Pyrgeometer sensors
- Temperature range: -40 do +80 °C
- Range: 0 – 2000 W/m2
- Temperature sensor: Thermistor
- Temperature sensor: Can be added if desired
Pyranometer (short-wave)
- Pyranometer ISO classification: second class
- Range: 305 – 2800 nm
- Calibration traceability
WRR Pyrgeometer (long-wave)
- Range: 4.500 – 50.000 nm
- Calibration traceability: NIST
- Window heating offset @ 1000 W/m2 solar radiation: <15 W/m2
- Heat output: 5 Watt @ 12VDC
Pyr – 01 Pyranometer
- Range: 400 – 1100 nm
- Signal output: 0-1 VDC
- Measuring range: 0 – 1400 W / ㎡
- Accuracy: <4%
- Response time: <50 ms
- Electricity supply: 12-24 VDC/7mA
BP-01 Pressure sensor
- Measuring range: 630 – 1130 mbar ili hPa (18,6 – 33.4in Hg.).
- Resolution: unlimited
- Operating temperature: -40 °C do + 85 °C
- Temperature compensation: 0 °C do + 70 °C
- Accuracy: ± 0,125% FS
- Power supply: 10 – 24V
- Power consumption:
- Active 5mA @ 12VDC
- Static 1.1mA @ 12VDC
- Signal output: 0-2 VDC
SU-10 UVA Sensor
- Spectrum: 315-380 nm
- Detector: GaAsp
- Linearity error: better than 1%
- Absolute Calibration error: typically <3% (max. 5%)
- The long stability: <± 2%
- Response time: 10 ms
HF-01 Heat flow sensor
- Sensitivity: 50 μV / W / m2
- Resistance (nominal):: 2 Ω
- Measuring range: 2000 do 2000W / m2
- The temperature dependence: <0,1% / °C
- Response time: ± 4 min (same ground)
HFT-3 Sensor heat flow to the ground
- Nominal calibration factor: 40 W / m2 / mV
- Resistance (nominal): 2 Ω
- Nominal size: 38.56mm, diameter * 3,93 mm thick
- Thermal conductivity: 1.22 Wm-1K-1
- Cable: Shield 2-conductor, 7.6m length
E-100 Meter evaporationa and evaporation vessel
- Dimensions:
- Height: 27 1/2 inches
- Diameter: 8 inches
- Float: 4 inch diameter plastic
- Potentiometer:
- Accuracy: 0.25%
- Rotation: continuous
- Resistance: 1000 oHm
- Operating temperature: -40 °C – +60 °C
IP Infracrveni Radiometar
- Field of View (FOV): 22 ° half angle
- Accuracy:
- -15 do +60 °C ± 0,2 ° C absolute accuracy
- ± 0,1 °C uniformity and repeatability
- -55 do +80 ° C ± 0,5 ° C absolute accuracy
- ± 0,3 °C uniformity and repeatability
- Wavelength: 8-14 um
- Response time: less than 1 second
- Operating ambient temperature:
- 55 °C to +80 °C
- 0 – 100% RH (non-condensing)
GT1 universal temperature probe (water, air, soil):
- Measuring rangee: -40 to +60 °C
- Accuracy:
- ± 0,3 °C(-20 °C to +40)
- ± 0,5 °C (-40 °C to +60)
- For the measurement of the air, soil and water temperature
GT2 Univerzalna temperaturna sonda:
- Measuring range: – 40 °C do + 90 °C
- Accuracy:
- ± 0,3 °C (- 20 to 40 °C)
- ± 0,5 °C (- 40 to + 60 °C)
- ± 0,7 °C (+ 60 to +90 °C)
RG-1 Pluviometer
- Sensor type: tipping bucket
- Hole diameter: 200 mm
- Material: bronze
- Sensitivity: 0,5 mm
- Accuracy:
- ± 0,5 mm below 20mm/hr
- 20mm/hr to 120 mm / hr ± 3%
- Signal output: non-contact reed switch
- Housing: inox
- Air balloon leveling included
RG-AB (type M and I) rain gauges
- Sensor type: tipping bucket
- Sensitivity: 0,2 mm (M serije); 0,01 inches (I series)
- Output: contact closure
- Housing material: UV stabilized ABS plastic
- Power supply: Not required
- Air balloon for leveling (M/I-AB )
UL-01 Sensor for measuring the level of water or snow with ultrasound
- Measuring range: 0,5 do 10 meters
- Beam Width: 22 degrees
- Accuracy: ± 1 cm ili 0,4 % of distance to the finish
- Resolution: 3 mm
- Temperature range: -30 do +70 °C
- Analog output: 0-2 VDC ili 0-5 VDC
- Power: 12 do 24 V, 50 mA
LW-4 Underwater pressure transducers
- Measuring range: 0 – 15 inches (second measuring range: 0 – 30 inches , 0 – 60 inches )
- Bursting pressure: 10 x full scale
- Static accuracy: ± 0,2% full scale measurement
- Power supply: 10 – 36 VDC
- Housing material: Steel SS304L
- Output: 0,4-0,2 VDC (ili 4 – 20 mA)
- Cable length: 7.5m ili 15m ili 30m standard
LW-5 Underwater pressure converters
- Measuring range: 0-5 through 0-300 psi
- Bursting pressure: 2,0 x full scale
- Static accuracy: ± 0,25% full scale measurement
- Power supply: 9-30 VDC
- Wetted material: SS316
- Working temperature : -10 °C to +60 °C
- Compensation temperature the range: 0 °C to +50 °C
- Output: 0,4 do 2,0 V ili 4-20 mA
- Fuses: polarity, exceed / short circuit
SP-20 Solar panel
- Max. power: 21 Watt
- The voltage at the peak: 17,4 VDC
- Electricity at the peak: 1.21A
- Optional USM 20 carrier
SP-30 Solar panel
- Max. power: 32 Watt
- The voltage at the peak: 17,4 VDC
- Electricity at the peak: 1.21A
- Optional USM 30 carrier